Product features
-
Independent R&D0-520V/820VDC output, covering 1250~15500kW, with equipment health management system.
-
High-performanceHigh power factor, low harmonics on the network side and fast dynamic response. Low output voltage and current ripple.
-
Flexible configurationModular design, parallel expansion of power, Ethernet, CAN, RS485, Ethernet, analog and digital interfaces.
-
Safe and reliableWater cooling design, high protection level, with reactive power compensation, automatic identification of AC phase sequence, linkage fault protection, AC insulation detection and other functions.
Operating conditions
-
-40℃~+50℃Ambient air temperature
-
≤95% (at 25℃)Monthly average maximum relative humidity of ambient air
-
2000mAltitude
Specifications
| Type | WDHI1250~15500 |
| Input voltage range | 306V/530V |
| Total current distortion rate | < 3% (> 30% of rated capacity) |
| Power factor | >0.99 |
| Maximum output power | 1250kW~15500kW |
| Maximum output current | 18900A |
| Output voltage range | 0~520V, 0~820V |
| Output current accuracy | ≤0.5% (maximum output current) |
| Output current ripple | ≤0.5% |
| Dynamic response time | <100ms |
| Output control mode | Voltage control/current control/power control |
| Communication interface | CAN,RS85,Ethernet |
| Cooling mode | water-cooling |
| Class of protection | IP32/IP54 |